Agni-Rodhak is a purpose-designed fire-protective coating from LIFEGUARD (United Fire Equipments Pvt. Ltd.) that combines active flame retardancy, thermal insulation, waterproofing and long-term durability in one product. Developed for modern risk environments where aesthetics, lifecycle cost and performance all matter, Agni-Rodhak is ideal for high-rise buildings, buses and coaches, rail & metro systems, hospitals, airports, malls and other public gathering places.

Agni-Rodhak is laboratory-validated by NABL-accredited testing and carries ISRO accreditation for specific thermal / material performance parameters — making it a trusted selection where compliance and performance evidence are essential for tenders, audits and safety certifications.


What Agni-Rodhak does

  • Slows flame spread across treated surfaces (reduces flame propagation and surface ignition).

  • Reduces surface temperature rise — provides thermal insulation that helps protect substrates and structural elements during the initial fire exposure window.

  • Provides waterproofing — prevents water ingress and supports substrate longevity in wet / humid conditions.

  • Improves durability — protects finishes against UV, abrasion and routine wear in transport and high-traffic environments.

  • Multiple application methods — spray, roller, brush or dip for maximum flexibility across substrates and contexts.


Where to use Agni-Rodhak (key sectors & examples)

High-Rise Buildings & Commercial Complexes

  • Façade substrates (where permitted by local codes), service ducts, cable trays, false ceilings, stair/lobby panels, escape route finishes.

Buses, Coaches & Fleet Vehicles

  • Interior panels, ceilings, luggage racks, driver cabins — spray or brush applications designed for vehicle manufacturing and retrofit.

Railways & Metro

  • Coach interiors, vestibules, underseat panels, luggage areas and depot workshop surfaces.

Hospitals & Healthcare Facilities

  • OT ceilings, corridor panels, equipment rooms and partitions — formulated to be low-odor and low VOC for patient safety zones.

Public Gathering Places

  • Auditoria, stadium concourses, exhibition halls, mall atriums and airport lounges — improves occupant safety and supports compliance.

Specialist installations

  • Cable trenches, server room enclosures, switchgear panels (where surface treatment is permitted), and protective coatings for wooden or composite architectural features.


Key benefits (B2B + Retail)

  • Fire performance: Significantly retards flame spread and lowers heat transfer to substrate. (Validated in NABL-accredited lab tests; ISRO-accredited for thermal control parameters.)

  • Dual protection: Combines flame retardancy with long-lasting waterproofing — ideal for mixed-use facades and outdoor vehicle bodies.

  • Versatile application: Spray, roller, brush or dip — suitable for factory application, workshop retrofits or on-site maintenance.

  • Aesthetic flexibility: Available matt / semi-gloss finishes and compatible primers to match interior/exterior design requirements.

  • Low lifecycle cost: Extends service interval and reduces maintenance on surfaces exposed to weather, UV and abrasion.

  • Regulatory readiness: Test reports from NABL labs and ISRO accreditation support tender and code compliance packages.


Technical highlights (typical / indicative)

Note: the values below are typical product guidelines. Exact technical datasheets, performance certificates and system build-ups are provided with project quotations.

  • Product type: Intumescent / flame-retardant polymeric coating with hydrophobic additives (H2O-displacing varnish system).

  • Coverage: ~6–8 m²/L per coat at 50–65 microns wet (coverage varies by substrate and application method).

  • Recommended coats: 2 coats minimum (primer + 1–2 top coats) — apply additional coats for enhanced thermal barrier as specified.

  • Drying time: Touch dry 30–60 min*, recoat 2–4 hours*, full cure 7 days* (*ambient 25°C, 50% RH — site conditions change cure times).

  • Service temperature: −20°C to +120°C (surface application); consult datasheet for elevated continuous temp.

  • Waterproofing rating: Meets typical water-penetration resistance standards for protective coatings (see datasheet).

  • VOC: Low-VOC formulation suitable for indoor use in healthcare and public settings.

  • Colours / finish: Standard RAL palette; custom colours available subject to minimums.

  • Compatibility: Bonds to primed steel, aluminium, timber, composites, gypsum boards and suitably prepared concrete; adhesion tests recommended prior to large application.


Application methods & best practices

Surface preparation (critical)

  • Remove loose paint, grease, oils, dust and corrosion products.

  • For metals: grit/blast or power-tool clean to specified Sa2½ / SSPC standards for best adhesion; apply anti-corrosion primer where required.

  • For timber and composites: sand to remove contaminants and apply compatible wood primer.

  • For masonry/concrete: ensure substrate is clean, dry and free of laitance; use appropriate primer/primer-sealer.

Application

  • Spray: Airless spray recommended for large areas and vehicle panels (use 15–21 thou tip depending on viscosity). Ideal for consistent film build and speed.

  • Roller: 9–12 mm nap microfibre roller for interiors and flat panels. Two-coat system to achieve specified DFT.

  • Brush: Use for touchups, edges and small repairs — high-quality synthetic brushes recommended.

  • Dip: For small components or removable parts — ensure controlled dwell time and uniform drainage; dry in dust-free conditions.

Curing & inspection

  • Maintain recommended ambient conditions during cure (temperature, humidity).

  • Measure dry film thickness (DFT) to ensure required thermal performance — record in QA logs.

  • Visual and adhesion tests post cure; provide coated sample to client for approval where needed.

Safety

  • Use PPE (respirator, gloves, eye protection) during application.

  • Ensure ventilation for indoor spray operations; use low-odor formulations in healthcare zones.

  • Collect and dispose of washings and waste per local regulations.


Performance validation & certifications

  • NABL-accredited laboratory testing: Fire performance (flame spread, surface ignition), water impermeability, adhesion and aging tests available.

  • ISRO accreditation: Validated thermal control / insulation performance for specified test matrices (useful in high-reliability projects).

  • Project documentation: Full test certificates, material declarations and batch traceability available for tenders and audits.


Typical system builds (examples)

  1. Interior public corridor (gypsum board): Primer (acrylic) → Agni-Rodhak 2 coats (spray/roller) → topcoat sealer (if required).

  2. Bus interior panels (composite): Surface prep → adhesion primer → Agni-Rodhak 1–2 coats (spray) → UV-protective clear topcoat.

  3. Rail coach vestibule (metal + laminate): Blast clean metal → anti-corrosion primer → Agni-Rodhak 2 coats (spray) → laminate finish.

  4. Hospital OT ceiling (low odor): Primer conforming to hospital spec → Agni-Rodhak low-VOC formulation 2 coats (roller) → final wipe and QA.

(We’ll supply full project-specific layer drawings and material quantities on enquiry.)


Maintenance & lifecycle

  • Inspection: Annual visual check for delamination, cracking or abrasion in high-traffic zones.

  • Touch-ups: Local sanding + single coat Agni-Rodhak patch for minor damage.

  • Refinish cycle: Typical 5–10 year lifecycle depending on exposure and abrasion; accelerated in heavy fleet use.

  • Cleaning: Mild detergent wash recommended; avoid aggressive solvents on painted surfaces.


Compliance & specification tips for procurement (B2B)

  • Include NABL test report and ISRO accreditation copy as part of technical bid.

  • Specify required DFT and number of coats (e.g., “Agni-Rodhak, 2 coats, minimum DFT 120 µm”).

  • Request sample panels for architectural approval and finish confirmation.

  • Ask for warranty terms (standard project warranty and extended options for transport fleets).

  • Include training clause for applicator and on-site QA witness testing in tender.


Safety & environmental information

  • Low VOC, water-based / water-borne formulations available for sensitive interiors (confirm variant).

  • Follow MSDS for handling, spill response and disposal.

  • Agni-Rodhak is designed to minimise environmentally harmful additives; full product environmental statement supplied on request.


FAQ — quick answers for specifiers & buyers

Q. Can Agni-Rodhak be applied over existing paint?
A. Minor touchups over sound coatings are possible after adhesion testing. For best fire performance, remove loose coatings and prime as recommended.

Q. Is Agni-Rodhak suitable for exterior façade use?
A. Yes — select the exterior variant with UV stabiliser and specify topcoat for long-term weathering. Confirm local code/regulatory permissions for façade treatments.

Q. Can we apply Agni-Rodhak in occupied hospitals without evacuation?
A. Low-VOC, low-odor variants are suited for occupied areas; however, spray application in critical zones should be scheduled with infection control and facilities teams.

Q. How many coats are needed for thermal protection?
A. Minimum 2 coats is typical; required DFT and extra coats depend on the thermal performance target — LIFEGUARD will model required DFT against project fire performance goals.

Q. Does Agni-Rodhak affect aesthetics?
A. Available in multiple finishes and colours; a primer + topcoat system can match architectural requirements while preserving protection.


SEO Keyword Bank (use across H1/H2, meta, alt text and on-page content)

Primary Keywords

  • Agni-Rodhak

  • Flame retardant coating Agni-Rodhak

  • Fire retardant coating for buildings

Secondary Keywords

  • Thermal control coating for buses

  • Waterproof flame retardant coating

  • ISRO accredited fire retardant coating

  • NABL tested fire protective coating

Long-Tail Keywords

  • Agni-Rodhak sprayable flame retardant for high-rise buildings

  • Roller applied fire retardant coating for railway coaches

  • Brush or dip applied flame retardant for hospital ceilings

  • Fire retardant waterproof coating for bus interiors


Meta Title & Meta Description (SEO ready)

Meta Title: Agni-Rodhak — Flame Retardant, Thermal Control & Waterproof Coating | ISRO & NABL Accredited

Meta Description: Agni-Rodhak by LIFEGUARD: sprayable, rollable, brushable and dip coatings that combine flame retardancy, thermal insulation, waterproofing and long durability for high-rise buildings, buses, rail, hospitals & public spaces. NABL tested & ISRO accredited.


Suggested page assets & on-page elements

  • High-resolution hero image of Agni-Rodhak being sprayed on a panel (alt text: “Agni-Rodhak spray application on interior panel”).

  • Downloadable PDF datasheet & NABL / ISRO certificates.

  • “Request sample panel” CTA that triggers project intake form.

  • Short video (30–60s) showing application by spray, roller and dip.

  • FAQ schema and product FAQ block for rich snippets.

  • Case study tile: “Pilot: Metro coach interiors — durability & thermal test results” (real project details to be added).


Call to action — specification, sampling & pilot projects

For project specifications, sample panels, test certificates or on-site trials, contact our engineering team:

United Fire Equipments Pvt. Ltd.
Manufacturer of ISI Certified Fire Safety Equipment
???? 8048034226
???? ufe126@gmail.com, info@lifeguardindia.in
???? www.lifeguardindia.in

Share: project type (building / bus / rail / hospital), substrate details, area (m²) and desired finish — we’ll return recommended system build-up, sample panel quote and tender-ready specification language.